Make the Stack Safer Before the Next Shake
Start With the Opening
Say what the fireplace burns now and what you have in mind. We ring back to set a visit and list what will be looked at.
The Work, in Short
The brick above the roofline stands with little to hold it, and it is the piece that came down on many Los Angeles houses in the 1994 quake. A retrofit gives it support or reduces its weight. Depending on the stack, that can mean steel members anchored to the roof framing, bands around the brick, or a lighter flue in place of the top courses. A gas conversion often makes the lighter route practical.
The Options, From Lightest to Most Thorough
Unreinforced brick and a wood frame respond to shaking in very different ways, and the joint at the roofline is where they part company. That is where chimneys crack, and the brick above it is what ends up on the roof, the driveway or the yard. Homes in Pico Rivera felt the 1987 Whittier Narrows quake at close range, and the 1994 quake reminded the whole region how many chimneys fail the same way. Retrofit work aims to keep that upper brick from coming down. The lightest option is bracing above the roof: steel members fixed to the upper stack and anchored into the rafters, which hold the top in place while the house moves. Bracing suits a chimney whose brick and mortar are still sound and whose height above the roof is modest. It does little for a stack that is already cracked through, because a brace cannot hold together brick that has already let go.
The next option works inside the house. Where the chimney passes each floor and the ceiling, steel straps can wrap the masonry and bolt into the joists, so the stack and the house are joined at several points instead of only resting side by side. This is usually paired with bracing above the roof. The third option is to reduce what can fall: shortening the stack to the lowest height the venting allows, or removing the upper part altogether and closing the roof. Owners moving to gas have a fourth: once the fireplace runs a gas insert or the chimney is retired in favor of a direct vent unit, the masonry above the roof can be replaced with a light framed chase finished to match the house, carrying a metal liner or nothing at all. That removes most of the weight from the place it does the most harm.
What We Look at and What You Receive
Every retrofit starts with the condition of the brick. We look from the roof at the height of the stack, the state of the mortar and any cracks at the roofline, and from the attic at how the chimney passes the framing and whether anything already ties it in. Where the flue matters, because the chimney will keep serving a fireplace, a camera run tells us whether the tile has been cracked by past shaking. Loose brick comes first in any plan: if the top courses are already moving, they have to be taken down and relaid or removed before a brace or strap can do any good. We describe the condition in plain terms and say which options make sense for this chimney and which do not. Two chimneys on the same block can call for different answers: a short, sound stack on a single story house may need only bracing, while a tall one with soft mortar may be better shortened. We also ask how you use the fireplace, since a chimney that no longer serves wood fires has far more options.
You then receive a written proposal that sets the suitable options side by side, each with its own figure and a description of what it involves on the roof and inside the house. If a gas conversion is on your list, we show how the two plans fit together, since a liner, a lighter top and a shorter stack can sometimes be done in one job for less than doing them separately. We do not cite code sections or promise rebates or insurance savings; if you are applying for a program, check its rules directly. Owners in Pico Rivera and Whittier often pair this visit with a Level 2 inspection so the flue and the structure are judged at the same time. If you decide to wait, the proposal still tells you which parts of the chimney to watch and what change would mean the work can no longer be put off.
Four Habits on Every Whitcomb Chimney Care Job
Measure, Then Order
Openings, flues and gas lines sized before parts are bought
Options Apart
Logs, insert and direct-vent written up one by one
Figures on Paper
A written number before work begins
First Fire Together
The new flame is lit while you watch
Chimney Seismic Retrofit by city
Pick a city to read how its houses, its weather and its streets bear on this job.
Nothing on the list by that name. Try the next city over, or send the street through the contact page.
Other Services
Chimney Sweep
Brushing and vacuuming for flues that still burn wood, and a clear-out of nests and rust flakes in flues already serving gas.
Read moreChimney Inspection
A written look at the flue, crown, cap and firebox, with the gas side read too when the fireplace has a burner.
Read moreChimney Repair
Repairs that get an old masonry flue ready for gas, or keep it sound for wood, priced once we have looked.
Read moreFireplace Inspection
A hearth-side look at firebrick, damper, glass and burner, for owners deciding whether to keep wood or move to gas.
Read moreFireplace Repair
Firebox, damper and door repairs on masonry and factory-built fireplaces, done so the opening can carry gas logs or wood.
Read moreChimney Level 2 Inspection
The deeper inspection: a recorded camera trip from firebox to cap, read alongside the roof, the attic and any gas hookup.
Read moreChimney Cap Installation
Caps chosen by fuel: a spark screen over wood, an open-flow top over gas, and the maker's own termination on direct-vent units.
Read moreChimney Flashing Repair
Water marks beside the hearth followed to the roof joint, then the metal reset, renewed or paired with a cricket.
Read moreChimney Masonry Repair
Worn joints, flaking brick and tired crowns rebuilt with a mortar soft enough for the brick it sits beside.
Read moreChimney Rebuilds
Stacks that lean, split from the house or failed in a quake rebuilt from sound brick, with the flue planned around gas.
Read moreFireplace Cleaning
Ash, soot and door glass on wood fireboxes; dust, webs and the ember bed on gas sets, laid back as drawn.
Read moreGas Fireplace Cleaning
A yearly reset for gas units: pilot hood, sensor rods, burner ports, embers and glass cleaned, then a leak test.
Read moreGas Fireplace Repair
Pilots that drop, burners that never catch and remotes that go dead, found with a meter before any part is ordered.
Read moreFireplace Remodel
Wood-to-gas makeovers that pick the appliance first, then build the surround, mantel and hearth to fit its listing.
Read moreFireplace Inserts
A sealed gas heater fitted inside your current firebox, with stainless vents to the crown and a fan for the room.
Read morePellet Stove Repair
Pellet stoves read in their start-up order, from exhaust fan to igniter to feed screw, until the failing step shows.
Read moreWood Stove Repair
Gaskets, firebrick, baffles and catalytic parts renewed on wood stoves, with a gas stove priced beside it if you ask.
Read moreGas Logs
Ceramic logs, a burner and a valve fitted to the opening you have, with the flue held open and the gas key in reach.
Read moreChimney Crown Repair
Crowns that have split, crumbled or never shed water sealed or recast, with a gap left so the flue tile can move.
Read moreDryer Vent Cleaning
Lint cleared from the duct between the machine and the outside hood, with the airflow read once the run is open.
Read moreChimney Liner Installation
Stainless liners run inside an old flue so a gas insert, log set or stove vents through a pipe of the right size.
Read moreChimney Leak Repair
Damp ceilings and stained walls near the hearth followed back to where the water actually enters, then sealed at that point.
Read moreChimney Waterproofing
A clear treatment for brick that sheds rain yet lets damp from gas exhaust work its way out.
Read moreChimney Damper Repair
Rusted, warped or loose dampers freed, rebuilt or replaced, and fixed open where a gas set needs the flue clear.
Read moreChimney Chase Cover
Rusted or dished tops on wood-framed chimneys swapped for new stainless, made to fit the frame they sit on.
Read more