A Tight Top for a Framed Chimney
Start With the Opening
Say what the fireplace burns now and what you have in mind. We ring back to set a visit and list what will be looked at.
The Work, in Short
Many houses with factory-built fireplaces have no brick at all; the vent pipe rises inside a wooden frame on the roof. Its metal lid is the only roof that frame has. When the lid rusts or sags, water collects and runs into the wood and onto the fireplace below. We take dimensions on the roof, have a new stainless lid bent to fit and fix it down with the pipe opening sealed.
How Chase Tops Fail
A factory built fireplace vents through a metal pipe, and that pipe usually runs up inside a framed box built onto the house. The box is sheathed to match the walls, and its top is closed by a metal cover, pierced where the pipe comes through and topped by the pipe's own cap. Builders often fitted thin galvanized covers that were flat or nearly so. Rain sits on a flat cover, the zinc wears off, the steel rusts and the middle sags until it holds a puddle. From there water drips through rust holes or around the pipe opening, and soaks the studs and sheathing inside the box before it reaches anything you can see from the room. Owners notice it as a stain on the wall near the fireplace, a musty smell, rust streaks down the outside of the chase or, eventually, rot they can push a finger into.
Gas conversions bring their own chase work. A direct vent fireplace built in a new spot may vent up through a newly framed chase, and that chase needs a cover sized to the gas vent pipe and its cap. A gas insert or stove fitted into an old factory built unit, where the unit's listing allows it, may use a smaller pipe than the original, so the opening in the old cover no longer fits. Even where nothing changes about the vent, a conversion is a good time to look at the chase top, because the appliance below is new and the water above it is not. Stainless covers with a raised middle that sheds rain, and sides that fold down over the top of the box, last far longer than the thin originals.
The Visit, the Cover and the Written Figure
On the roof we measure the chase top exactly, note where the vent pipe sits and how big it is, and look at the cap. We lift the old cover where we can to see the framing beneath. If the wood is sound, a new cover is all that is needed. If the top plates or sheathing have rotted, the rot has to be cut out and replaced before the new cover goes on, or the cover will be fixed to wood that will not hold it. From inside, we look at the top of the fireplace and the wall around it for water marks. Each finding goes into plain notes with what it means for the repair. Chases on two story homes or steep roofs need more setup, and we mention that before booking so the access is planned rather than discovered.
Each cover is cut and bent to your chase's own dimensions, so the written figure follows from those measurements, the thickness of stainless chosen, the pipe opening, and any carpentry the framing needs. If the vent cap is rusted or the wrong type for the appliance, replacing it at the same time is usually sensible, and installed caps on this site are quoted after we measure. If the factory built fireplace itself is worn out, we can also discuss replacing it with a gas unit designed for the space. Owners in Pico Rivera and Downey with framed chimneys often find the cover is the cause of a leak they had blamed on the roof. Fitting a new cover takes a measuring trip and an install trip, since each one is made to order; if water is coming in meanwhile, the old cover can be patched to hold until the new one arrives.
Four Habits on Every Whitcomb Chimney Care Job
Measure, Then Order
Openings, flues and gas lines sized before parts are bought
Options Apart
Logs, insert and direct-vent written up one by one
Figures on Paper
A written number before work begins
First Fire Together
The new flame is lit while you watch
Chimney Chase Cover by city
Pick a city to read how its houses, its weather and its streets bear on this job.
Nothing on the list by that name. Try the next city over, or send the street through the contact page.
Other Services
Chimney Sweep
Brushing and vacuuming for flues that still burn wood, and a clear-out of nests and rust flakes in flues already serving gas.
Read moreChimney Inspection
A written look at the flue, crown, cap and firebox, with the gas side read too when the fireplace has a burner.
Read moreChimney Repair
Repairs that get an old masonry flue ready for gas, or keep it sound for wood, priced once we have looked.
Read moreFireplace Inspection
A hearth-side look at firebrick, damper, glass and burner, for owners deciding whether to keep wood or move to gas.
Read moreFireplace Repair
Firebox, damper and door repairs on masonry and factory-built fireplaces, done so the opening can carry gas logs or wood.
Read moreChimney Level 2 Inspection
The deeper inspection: a recorded camera trip from firebox to cap, read alongside the roof, the attic and any gas hookup.
Read moreChimney Cap Installation
Caps chosen by fuel: a spark screen over wood, an open-flow top over gas, and the maker's own termination on direct-vent units.
Read moreChimney Flashing Repair
Water marks beside the hearth followed to the roof joint, then the metal reset, renewed or paired with a cricket.
Read moreChimney Masonry Repair
Worn joints, flaking brick and tired crowns rebuilt with a mortar soft enough for the brick it sits beside.
Read moreChimney Rebuilds
Stacks that lean, split from the house or failed in a quake rebuilt from sound brick, with the flue planned around gas.
Read moreFireplace Cleaning
Ash, soot and door glass on wood fireboxes; dust, webs and the ember bed on gas sets, laid back as drawn.
Read moreGas Fireplace Cleaning
A yearly reset for gas units: pilot hood, sensor rods, burner ports, embers and glass cleaned, then a leak test.
Read moreGas Fireplace Repair
Pilots that drop, burners that never catch and remotes that go dead, found with a meter before any part is ordered.
Read moreFireplace Remodel
Wood-to-gas makeovers that pick the appliance first, then build the surround, mantel and hearth to fit its listing.
Read moreFireplace Inserts
A sealed gas heater fitted inside your current firebox, with stainless vents to the crown and a fan for the room.
Read morePellet Stove Repair
Pellet stoves read in their start-up order, from exhaust fan to igniter to feed screw, until the failing step shows.
Read moreWood Stove Repair
Gaskets, firebrick, baffles and catalytic parts renewed on wood stoves, with a gas stove priced beside it if you ask.
Read moreGas Logs
Ceramic logs, a burner and a valve fitted to the opening you have, with the flue held open and the gas key in reach.
Read moreChimney Seismic Retrofit
Brick stacks above the roof given support from the house or made lighter, often planned alongside a move to gas.
Read moreChimney Crown Repair
Crowns that have split, crumbled or never shed water sealed or recast, with a gap left so the flue tile can move.
Read moreDryer Vent Cleaning
Lint cleared from the duct between the machine and the outside hood, with the airflow read once the run is open.
Read moreChimney Liner Installation
Stainless liners run inside an old flue so a gas insert, log set or stove vents through a pipe of the right size.
Read moreChimney Leak Repair
Damp ceilings and stained walls near the hearth followed back to where the water actually enters, then sealed at that point.
Read moreChimney Waterproofing
A clear treatment for brick that sheds rain yet lets damp from gas exhaust work its way out.
Read moreChimney Damper Repair
Rusted, warped or loose dampers freed, rebuilt or replaced, and fixed open where a gas set needs the flue clear.
Read more